Institute for Catastrophic Loss Reduction

Building resilient communities

Home

About Us

Strategic Plans

Governance

Board of Directors

Management Committee

Advisory Committee

Research Associates

Staff Profiles

Homeowners

Be Prepared!

Research for Safer Homes

New Homes

Existing Homes

Earthquake Risk Tool

Outil de Cartographie.

Communities

RSVP for Cities

Understanding Hazards

Research Network

Businesses

Open for Business (TM)

Protecting Our Kids

Membership

Become a Member

General Membership

Associate Membership

Member Companies

Partners

Resource Centre

Magazine Articles

Hazard Research Papers

Cat Tales eNewsletters

Homeowner safety

Focus on

Workshop slide archive

Icestorm 98 Main page

Books

ICLR Health Presentations

Workshops

Friday Forums

Conferences

Media Centre

Speeches

Press Releases

Loading
Back to Flood/ Drought Papers
Back to Hazard Research Papers

Flood/drought papers
Urban flooding in Canada
Lot-side risk reduction through voluntary retrofit programs, code interpretation and by-laws
Dan Sandink
February 2013


Abstract


While it has been previously reported that resolution of code enforcement issues may result in reduced vulnerability to extreme natural events, issues surrounding code interpretation have not previously been studied. Among other topics, this study investigated interpretation of code wordings that relate to installation of backwater valves to protect homes from sewer backup—a significant cause of basement flooding associated with extreme precipitation events and urban flooding.

Despite consistent application of code wordings related to backwater valves across the regions of Canada represented in this study, it was found that there are differing interpretations of code wordings, which resulted in differing reported frequencies of installation of backwater valves on both sanitary/combined and storm sewer service connections. Thus, the primary recommendation of this report is that sentences in the National Plumbing Code and provincial building and/or plumbing codes that relate to installation of backwater valves to protect against sewer backflow be reworded or clarified to ensure they are clearly and consistently interpreted and applied.

There are many advantages of installing backwater valves in new homes. Due to the unpredictable nature of extreme rainfall events and the unpredictability of infiltration and inflow (I/I) in relatively new, separated sewer systems, it is often impossible to identify which regions of an urban municipality are exposed to sewer backup risk until wide spread or regional sewer backup events have occurred. It is also more economical to install backwater valves in new homes when compared to retrofitting valves into existing homes. For example, several Canadian municipalities provide partial retrofit subsidies of several thousand dollars for the retrofit of backwater valves, while installation of valves in new homes costs approximately $250. Requiring installation of valves in new homes would also help offset relatively low uptake frequencies for municipal subsidy programs aimed at encouraging homeowners to adopt urban flood risk reduction measures.

The study revealed that backwater valve code wording is interpreted differently across the country, though there is greater interpretation consistency in some regions than in others. Specifically, the survey revealed that 19% of British Columbia respondents, 81% of Alberta respondents, 86% of Saskatchewan respondents, 72% of Manitoba respondents, 26% of Ontario respondents and 58% of respondents from New Brunswick and Nova Scotia interpreted code wordings in a manner that required backwater valves to be installed in all or most new homes. The study further revealed that interpreting code wording in this manner was strongly correlated with a higher frequency of installation of backwater valves in new homes, indicating the importance of code interpretation for backwater valve installation.

This study recommends that code wordings related to protection from backflow through the use of backwater valves be clarified, or that provincial and national code authorities provide guidance to local authorities about how code wordings related to protection of homes from sewer backflow should be interpreted. This guidance should outline that code wordings be interpreted in a way that requires the mandatory installation of backwater valves in all or most new Canadian homes. The substantial costs associated with sewer backup insurance claims, the legal liability of municipalities generated by regional sewer backup events, health and home liveability risks posed to households created by sewage flooding and the fact that urban flooding and sewer backup occurrences are likely to increase as a result of increasing frequency of extreme rainfall caused by climate change justify a mandatory requirement for installation. The need for lot-side protection from backflow is exacerbated by the changing nature of stormwater runoff caused by increasing urban development and the unpredictable nature of I/I leading to surcharging in separated sewer systems.

Urban flooding in Canada: Lot-side risk reduction through voluntary retrofit programs, code interpretation and by-laws (pdf)
Digital Issuu version








The Institute for Catastrophic Loss Reduction

Toronto Office
20 Richmond Street East, Suite 210, Toronto, Ontario M5C 2R9
Tel: (416) 364-8677
Fax: (416) 364-5889

London Office
Boundary Layer Wind Tunnel Laboratory
Western University
1151 Richmond Street, London, Canada N6A 5B9
Tel: (519) 661-3234
Fax: (519) 661-4273